What are you working on?

Find a calculator, explore a formula, or learn the method.

THE ENGINEERING REFERENCE / GUIDE

Regressing Antoine Coefficients: Selecting Data, Units, and a Fitting Range

Short Answer

Regressing Antoine coefficients comes down to three decisions: fit data that spans the temperature range you will actually use, keep the units and logarithm conventions consistent, and restrict both the fit and its use to that range. This article explains each decision and the two standard fitting routes.

Regressing Antoine coefficients is less about the algebra, which is simple, and more about three decisions made before the regression runs: which vapor-pressure data feeds the fit, which units and logarithm conventions the coefficients will carry, and which temperature range the equation is allowed to serve. A fit that respects those constraints behaves predictably in later calculations; one that ignores them can return statistically tidy constants that compute the wrong pressures. This article works through each decision, the two standard fitting routes, and the checks that separate a usable coefficient set from a fragile one.

What the Antoine equation describes

The Antoine equation is an empirical, temperature-explicit description of how the vapor pressure of a pure substance varies with temperature. It was first proposed by the French researcher Ch. Antoine in 1888 and is generally presented as a practical outgrowth of the Clausius-Clapeyron relation. In its basic form it reads log10 P = A – B/(T + C), where P is the absolute vapor pressure, T is the temperature, and A, B and C are substance-specific coefficients determined by regression. A simpler two-constant version omits C; the extra parameter is what gives the equation its flexibility over a bounded temperature interval (Knowino).

Because the equation circulates in several conventions, the first step of any regression – or of any use of published coefficients – is to pin down the exact form. Some sources write log10 P = A + B/(T + C) and expect the fitted B to come out negative; others write A – B/(T + C) with a positive B; a Carnegie Mellon University course exercise, for example, fits the plus-sign variant directly to temperature and pressure data (CMU). The logarithm is customarily base 10, but fitting with the natural logarithm is equally valid. Neither choice changes the physics; both change the numbers produced and how the coefficients must be used afterward.

Choosing vapor-pressure data for the fit

Antoine coefficients are only as good as the vapor-pressure data behind them. Span matters more than raw quantity: the data should straddle the temperatures at which the equation will actually be used, because interpolation inside the fitted range is far more reliable than extrapolation beyond it. When the equation will be used near atmospheric conditions, the data should reach the normal boiling point so the fit is anchored where it matters.

There is a structural reason for this caution. The Antoine equation is not flexible enough to represent the entire vapor-pressure range from the triple point to the critical point, which is why two sets of coefficients are commonly published for a single substance – one for temperatures below the normal boiling point and another above it. A single set stretched across both regions compromises accuracy precisely where it is needed most.

On quantity: three unknown constants require at least three data points, but three is the mathematical minimum rather than a practical target. More points, spread evenly across the range, damp the influence of any single suspect measurement and make residuals easier to interpret. When only two reliable points are available – a situation Stephen Hall poses in a rules-of-thumb column on regressing vapor-pressure equations – the standard remedy is to fix one of the three constants, usually C, at a published or estimated value and fit the remaining two through the two points. Hall’s column pairs the regression algebra with a VBA function routine for performing such property calculations in Excel.

Units, logarithm base, and sign conventions

Antoine coefficients silently encode three choices: the pressure unit, the temperature unit, and the logarithm base. Hall notes that the customary units are mmHg and degrees Celsius, although any units may be used, and that the customary base-10 logarithm may equally be replaced by the natural logarithm. The consequence is easy to overlook: a set of A, B and C fitted as mmHg over degrees C with log10 will return wrong pressures if entered into an equation implemented in kPa and kelvin. The calculation still runs, which is exactly why the error tends to go unnoticed.

PressureTemperatureLog baseTypical context
mmHg (Torr)deg Clog10Classic handbook coefficient tables
kPadeg Clog10Modern spreadsheet and simulation work
kPa or barkelvinln or log10Thermodynamic-style fits alongside other property correlations

Any consistent combination is legitimate; the mistakes come from mixing them. Exact algebra can convert between some conventions when both sets share the same equation form and sign convention: expressing temperature in kelvin instead of degrees C is equivalent to increasing C by 273.15 while leaving A and B unchanged; switching from log10 to the natural logarithm multiplies A and B by ln 10; changing pressure units shifts A by the logarithm of the conversion factor. These shortcuts rely on clean documentation of the original convention. When provenance is unclear, the safer route is to refit from the original data rather than transform coefficients of uncertain pedigree.

Setting the fitting range

Define the fitting range before running the regression, not after seeing the results. The range should match the intended service of the equation. A fit destined for distillation calculations that span overhead and bottoms conditions may legitimately be split into two coefficient sets around the normal boiling point rather than stretched across both. Archive or publish coefficients together with their valid range; a coefficient set without its range is an incomplete engineering record.

Extrapolation deserves explicit restraint. The temperature-explicit form makes the equation effortless to evaluate at any temperature, including temperatures where it was never fitted, and near the critical region its functional shape is simply wrong. If a calculation genuinely requires pressures outside the fitted window, obtain or fit a set for that window, or move to a correlation built for the wider range, rather than trusting an extrapolated Antoine value.

How to run the regression

Two fitting routes dominate practice. The classical route linearizes the equation and solves it with multiple linear regression. CheGuide works the algebra: starting from log P = A – B/(T + C), the equation rearranges to y = a0 + a1x1 + a2x2 with y = log P, x1 = 1/T and x2 = log P/T. Excel’s LINEST function then returns the three intermediate constants, from which A equals a0, C equals -a2, and B follows from the identity a1 = AC – B. CheGuide demonstrates the workflow on experimental n-decane vapor-pressure data running from low pressures to atmospheric (CheGuide).

The second route is nonlinear least squares, which fits the equation in its native form. The Carnegie Mellon exercise mentioned above fits log10 P = A + B/(T + C) directly to a data set and asks for confidence intervals on each parameter – statements about the Antoine constants themselves, rather than only about intermediate regression terms. Standard tools handle either route: spreadsheet functions such as LINEST, solver-based optimization, numerical libraries such as those in Python, or VBA routines of the kind Hall provides.

  1. Define the temperature range in which the equation will be used.
  2. Collect at least three – preferably many more – experimental points spanning that range, including the normal boiling point when atmospheric conditions matter.
  3. Fix the convention: equation form and sign convention, pressure unit, temperature unit, and logarithm base.
  4. Convert every data point to that convention before fitting.
  5. Fit the constants by linearized multiple regression or nonlinear least squares.
  6. Back-calculate vapor pressures and inspect residuals in both pressure and log pressure.
  7. Validate against withheld data points and check that the fit reproduces the normal boiling point.
  8. Record the coefficients together with their form, units, log base, and valid range.

Checking goodness of fit

A regression can report tidy statistics while misrepresenting the underlying data. Judge the fit the way the equation will be used: back-calculate vapor pressure at each experimental temperature and examine residuals in pressure as well as in log pressure, because the two views emphasize different parts of the range. A log-space fit spreads relative error roughly evenly across decades of pressure, which is usually desirable, but it can hide a systematic curved trend at the extremes. Plotting the fitted curve over the data – constrained to the fitted range – together with a check at the normal boiling point catches most problems before the coefficients reach a flowsheet.

Common mistakes to avoid

  • Mismatched units or log base. Coefficients fitted as mmHg/deg C/log10 inside a kPa/kelvin equation produce a plausible-looking but wrong answer. Store the units alongside the constants.
  • Sign-convention confusion. Entering plus-sign-variant coefficients into a minus-sign form reverses the temperature trend of the predicted pressure entirely.
  • One set across both sides of the normal boiling point. Where accuracy matters on both sides, two fitted sets beat a single compromise fit.
  • Extrapolation. One coefficient set cannot reliably serve the whole span from triple point to critical point; respect the fitted window.
  • Two points, three constants. Without a third point, one constant must be fixed knowingly, not discovered by the fit.
  • Trusting a single statistic. A lone correlation coefficient says little; residuals in pressure and in log pressure say much more.

Handled this way, Antoine regression is a dependable, transparent exercise: data chosen for the range of service, a convention fixed and documented, constants fitted by either linearized or nonlinear routes, and the result validated against residuals and withheld points before anyone depends on it.

FAQ

How many data points do I need to regress Antoine coefficients?

Three is the mathematical minimum because the equation has three unknown constants, but more points spread across the intended temperature range give a more dependable fit and easier residual checks. With only two reliable points, one constant - usually C - must be fixed at a published or estimated value before fitting the other two.

Can Antoine coefficients fitted in one unit system be reused in another?

Only with care, and only when both sets share the same equation form and sign convention. In that case exact algebra applies: switching from degrees C to kelvin increases C by 273.15, switching from log10 to natural log multiplies A and B by ln 10, and changing pressure units shifts A by the logarithm of the conversion factor. If the source documentation is unclear, refit from the original data instead.

Why do many references list two sets of Antoine coefficients for one substance?

Because the equation is not flexible enough to represent the entire vapor-pressure range from the triple point to the critical point. One set fitted below the normal boiling point and another fitted above it each track the data better than a single compromise set.

Should I fit vapor pressure directly or in log form?

Both are legitimate. Linearized regression methods inherently fit log-transformed values, which distributes relative error evenly across the pressure range. Whichever you choose, inspect residuals back in pressure as well, since that is how the coefficients will be used, so a log-space statistic alone does not mask curvature at the range extremes.

References

  1. Hall, Stephen. 'Rules of Thumb: Vapour Pressure and Viscosity Equations.' The Chemical Engineer, 31 March 2022. https://www.thechemicalengineer.com/features/rules-of-thumb-vapour-pressure-and-viscosity-equations/
  2. CheGuide. 'Curve fitting data to an Antoine Equation.' https://www.cheguide.com/antoine_eqn.html
  3. Kitchin, John. 'Antoine equation.' Course assignment, f23-06623, Carnegie Mellon University. https://kitchingroup.cheme.cmu.edu/f23-06623/assignments/antoine-fit/antoine-fit.html
  4. 'Antoine equation.' Knowino. https://www.theochem.ru.nl/~pwormer/Knowino/knowino.org/w/index1045-3.html?stable=1&title=Antoine_equation

Related Terms

Leave a Reply