Reynolds Number Calculator

Calculate Reynolds number from mean flow speed, a clearly defined diameter, and either dynamic viscosity with density or kinematic viscosity directly. Convert SI and engineering units, follow the calculation, and check the approximate flow regime for a full circular pipe.

FLUID FLOWSingle-phase · Newtonian fluid

01 Define the flow conditions

Use fluid properties at the same operating conditions. Kinematic viscosity does not need density.

Use actual internal diameter, not nominal pipe size or outside diameter.

Changing units converts entered values. cP and cSt measure different properties.

Calculations run in your browser. Input values are not sent to the server.

02 Read the Reynolds number

Reynolds number · Re

—Dimensionless

Enter the flow conditions to begin.

Engine 1.0.0Read the method, assumptions, and sources below.

Formula and method

Reynolds number compares inertial effects with viscous effects. With mean cross-sectional speed V and characteristic diameter D:

Re = ρVD/μ = VD/ν, where ν = μ/ρ.

Density ρ is in kg/m³, dynamic viscosity μ in Pa·s, and kinematic viscosity ν in m²/s. The engine converts speed to m/s and diameter to m before calculating Re, which is dimensionless. Kinematic viscosity mode does not require density. Use property values at the same fluid composition, phase, temperature, and pressure.

Choose the correct diameter

  • Circular pipe: use the actual internal diameter of the flow passage. Nominal pipe size and outside diameter are not interchangeable with internal diameter.
  • Other fully filled ducts: choose hydraulic diameter and supply Dh = 4A/Pw, where A is the open flow area and Pw the wetted perimeter. For a full circular pipe this reduces to its internal diameter.
  • The entered speed must be the mean speed through that same flow area, not the centerline speed. A hydraulic diameter does not make every duct behave like a circular pipe; geometry-specific correlations still apply.

Flow-regime guidance

Circular-pipe Reynolds numberApproximate classification
0 < Re < 2300Laminar
2300 ≤ Re ≤ 4000Transitional
Re > 4000Turbulent
Re = 0No flow

These are engineering guides for ordinary internal circular-pipe flow, not universal transition guarantees. Inlet disturbances, roughness, and development affect transition. The calculator uses the unrounded result, treating only floating-point roundoff at a boundary as equality. Hydraulic-diameter mode reports Re without assigning a circular-pipe regime.

Assumptions and validity

  • A single-phase Newtonian fluid with representative bulk properties and a fully filled flow passage. For non-Newtonian, multiphase, open-channel, or external flows, use the appropriate Reynolds definition and transition criteria.
  • Speed must be nonnegative. Density, diameter, and the selected viscosity must be positive. Zero speed produces Re = 0 and is labeled “No flow.” Numerical overflow and nonzero underflow are rejected.
  • Dynamic and kinematic viscosity are different quantities: 1 cP = 0.001 Pa·s; 1 cSt = 10⁻⁶ m²/s. They cannot be interchanged without density. Imperial dynamic viscosity here is mass-based lbm/(ft·s), not lbf·s/ft².
  • No properties are looked up automatically. A Reynolds number alone does not calculate pressure drop, friction factor, entrance length, or a heat-transfer coefficient.

Worked example

Assume a fluid has density 1000 kg/m³ and dynamic viscosity 1 cP. It flows at a mean speed of 2 m/s through a pipe with actual internal diameter 50 mm. Convert μ = 0.001 Pa·s and D = 0.05 m.

Re = 1000 × 2 × 0.05 / 0.001 = 100,000. This falls in the turbulent circular-pipe guide range. Equivalently, ν = 0.001/1000 = 10⁻⁶ m²/s = 1 cSt, so Re = 2 × 0.05 / 10⁻⁶ = 100,000. These property values are illustrative assumptions, not a material-property dataset. Select “Load example” to reproduce the case.

Sources and calculation version

Changelog: engine 1.0.0 introduces two viscosity methods, internal/hydraulic diameter bases, unit conversion, circular-pipe regime guidance, zero-flow handling, and input validation. Parameter source: your fluid and flow conditions; no property dataset is used. Engineering review status: independent review pending.