What are you working on?

Find a calculator, explore a formula, or learn the method.

THE ENGINEERING REFERENCE / GUIDE

Reading a Pump Curve: Shutoff Head, Runout, and Best Efficiency Point

Short Answer

A pump curve maps the head a centrifugal pump produces at each flow rate at a given speed, along with its efficiency, power draw, and suction requirements. The three key landmarks are shutoff head at zero flow, the best efficiency point (BEP) where efficiency peaks, and runout at the far right end of usable flow. Operating a pump with its duty point near the BEP minimizes energy cost, vibration, and wear.

A centrifugal pump curve is the manufacturer’s concise description of what a specific pump will do at a specific speed: for every rate of flow, it states how much head the pump can develop, how much power it will draw, how efficiently it converts that power into liquid motion, and how much suction energy it needs to avoid cavitation. Three landmarks organize almost everything on the chart. The shutoff head sits at the zero-flow end, the best efficiency point (BEP) marks the peak of the efficiency curve, and runout is the far right end of the usable curve. Locating these three points, and knowing what each implies, is the core skill in reading a pump curve and the starting point for choosing a pump that runs economically and lasts.

Centrifugal pumps are the standard choice where high flow rates, smooth and nonpulsating delivery, and flow regulation over a wide range are needed. They have few moving parts, minimal wear from normal operation, and are compact and easy to disassemble for maintenance, which is why they dominate industrial, municipal, commercial HVAC, and agricultural service, as the U.S. Department of Energy’s pumping-systems tip sheet notes. Their performance, however, is entirely defined by two things: the curve and the system the pump is connected to.

What a Pump Curve Shows

The most important line is the head-flow curve, often called the H-Q curve. Flow rate is plotted on the horizontal axis and head on the vertical axis, at a constant pump speed. The relationship is inverse: as flow through the pump decreases, the head it develops rises, and as flow increases, head falls, as the Wilo USA pump training resources explain. Head itself is the amount of energy the pump must impart to move water to its destination, expressed as feet (or meters) of the pumped liquid. Working in head rather than pressure units is deliberate: the pressure produced by a given head depends on the liquid’s density, so a head-based curve stays meaningful across different fluids and sums directly with static lift and friction losses.

A full performance chart layers three more sets of information on the same flow axis: an efficiency curve, often drawn as contoured efficiency islands surrounding the BEP; a power curve showing the brake horsepower required at each flow; and an NPSH required curve, where NPSH stands for Net Positive Suction Head, the suction-side energy the pump needs to keep the liquid from flashing to vapor. Structured introductions to curve reading, such as Grundfos trainer Jim Swetye’s How to Read a Pump Curve webinar for Pumps & Systems, organize the chart in exactly this way: knowing what information is on the curve and how it is formatted.

One caution before reading anything: a published curve applies to a specific impeller diameter, a specific rotational speed, and usually a specific fluid (clean water). Trimming the impeller or changing speed shifts the curve, and a variable-speed drive effectively produces a family of curves. Always confirm that the curve matches the pump as it is actually configured.

Shutoff Head: The Zero-Flow Limit

Shutoff head, sometimes called deadhead head, is the head the pump develops when it delivers no flow at all, for example against a closed discharge valve. It is the highest point of the head-flow curve. Even with zero useful output, the impeller still pressurizes the liquid and churns it in recirculation inside the casing, so shutoff head is a finite, readable number rather than a limit of the pump’s capability.

Shutoff head has two practical uses:

  • A system-limit check. If the static component of your system, meaning vertical lift plus any pressure head required at the destination, exceeds the pump’s shutoff head, the pump cannot begin delivering flow. The check valve stays shut and the pump simply spins against a static column.
  • A starting and motor-sizing reference. Discharge pressure at startup is bounded by the shutoff head, and for most radial-flow centrifugal pumps the power drawn at shutoff is near its minimum, which matters when verifying that the motor can bring the pump up to speed.

It is equally important to know what shutoff head is not: a normal operating point. Running a pump deadheaded for more than a few moments puts all the input power into churning a small volume of liquid. The liquid temperature rises quickly, which can damage seals, cause the pump to vapor-bind, and eventually distort hot-running parts. If a pump must run against a closed valve, open a bypass line or stop the pump rather than letting it sit on shutoff.

Best Efficiency Point: The Heart of the Curve

The best efficiency point (BEP) is the flow rate at which the efficiency curve peaks, meaning the flow at which the pump converts the largest share of shaft power into productive liquid movement. On the chart it usually appears where the highest efficiency island is centered along the head-flow curve, and catalog tables typically list its flow and head directly.

Operating at or very near BEP is the target for several reasons:

  • Energy cost. Once a pump is installed, its dominant life-cycle costs are the energy it consumes and the maintenance it needs, and both depend heavily on how well the pump was matched to the job, as the LSU AgCenter pump-curves publication emphasizes.
  • Reliability. Hydraulic loads on the impeller and shaft are best balanced at BEP. Operating far to either side increases vibration, shaft deflection, and radial load, which shortens the life of bearings and mechanical seals. Industry guidance commonly describes a preferred operating region of roughly 70 to 120 percent of BEP flow.
  • Stable performance. Internal flow patterns are cleanest at BEP. Well to the left or right of it, damaging recirculation can develop on both the suction and discharge sides of the impeller.

This is why experienced practitioners select a pump by finding the model whose BEP sits close to the flow the system will actually demand, rather than buying oversize capacity as a hedge. As the Department of Energy tip sheet stresses, an efficient pumping system depends on the relationships among fluid flow rate, piping layout, control methodology, and pump selection, and the application must be clearly understood before a pump is chosen.

Runout: The Far Right End

Runout is the point at the far right end of the published head-flow curve: the maximum flow the pump can deliver when the head it must produce is small. Beyond runout the curve drops away steeply, and the manufacturer is no longer promising stable, predictable performance. Runout is a limit, not a destination.

As flow approaches and passes runout:

  • Suction demands rise. The NPSH required curve climbs steeply at high flow, so the margin between available and required suction head shrinks and cavitation, the formation and violent collapse of vapor bubbles, becomes likely. Cavitation typically sounds like gravel passing through the pump, and it erodes impeller surfaces over time.
  • Power demand rises. For most radial-flow centrifugal pumps, brake horsepower increases with flow, so a motor sized to run comfortably near BEP can be pushed toward overload near runout.
  • Structural loads rise. High velocities and unbalanced hydraulic forces increase vibration, shaft stress, and wear at the seals and bearings.

The three landmarks in summary:

LandmarkLocation on curveWhat it tells youMain caution
Shutoff headZero flow; highest headMaximum pressure available; checks whether system static head can be overcomeOnly brief operation; liquid heats when deadheaded
BEPPeak of the efficiency curveBest energy use and lowest vibration and wearChoose a pump whose BEP matches the actual duty flow
RunoutFar right end of curveMaximum flow capabilityCavitation and motor overload risk

Finding the Duty Point: Where Pump Meets System

The pump curve alone does not tell you the flow you will get. A pump connected to piping operates wherever its curve intersects that system’s system curve, producing the duty point (also called the operating point). The system curve combines the fixed static head, meaning lift plus any pressure difference the system must overcome, with friction losses in the piping, which grow roughly with the square of the flow rate. The system curve therefore rises steeply toward the right.

As demand changes, the operating point slides along the pump curve. Throttling a discharge valve adds restriction, steepening the system curve and moving the duty point left toward higher head and lower flow; slowing the pump with a variable-speed drive lowers the pump curve itself. Good selection puts the duty point near BEP under normal conditions, so that everyday control movements keep operation inside the efficient, low-vibration region instead of pushing it toward shutoff or runout.

Reading a Pump Curve Step by Step

  1. Confirm the curve’s conditions: model, impeller diameter and trim, speed, and fluid. Published curves normally assume clean water; corrosive, abrasive, or solids-laden liquids change the real numbers, and pumps purpose-built for dirty or sandy water generally trade efficiency for durability.
  2. Locate the shutoff head on the vertical axis and compare it with the static head of your system. If the static requirement is higher than shutoff head, this pump cannot start delivering flow.
  3. Trace the head-flow curve to your required flow and read the head available there. That head must cover the system’s static lift plus its friction losses at that flow.
  4. Find the BEP: read its flow and head, then check where your expected duty point sits relative to it. A large deviation suggests a different pump or a different impeller trim.
  5. Read efficiency at the duty point and use the power curve to size or verify the motor, taking the manufacturer’s service factor into account.
  6. Check NPSH: read NPSH required at the duty point and compare it with the suction head your system provides through its piping design. A comfortable positive margin is essential, especially at high flows.
  7. Check the operating region: confirm the duty point lies within the manufacturer’s stated preferred or allowable operating region, clear of runout on the right and of the minimum continuous flow limit on the left.

Common Mistakes When Reading Pump Curves

  • Treating the curve as a flow guarantee. The curve shows capability; the system decides the actual flow at the duty-point intersection.
  • Specifying toward runout for headroom. Buying a larger pump so it can be run far right usually means accepting cavitation risk, higher power draw, and shortened life in return.
  • Oversizing to be safe. A pump whose BEP sits far above the actual duty flow operates well left of BEP, where recirculation and vibration quietly shorten seal and bearing life.
  • Ignoring the fluid. All water is not the same: salty, acidic, sandy, or solids-laden liquids affect both performance and pump type, and clean-water curves need correction before being applied to them.
  • Using a curve that does not match the hardware. Impeller trims, speed changes, and internal wear each shift the curve, so verify against nameplate data and the as-built configuration before troubleshooting.

Practical Takeaways

To read any pump curve, find three points first: the shutoff head at the top left, the BEP near the middle where efficiency peaks, and runout at the right end. Then ask where your system’s duty point falls relative to the BEP. A pump whose duty point sits at BEP runs cheaper, quieter, and longer than the same pump pushed toward either end of its curve. When the answer is not clear from catalog data alone, assemble your system’s required flow, static head, and piping details and consult the manufacturer’s performance data or a pump-sizing tool: the published curve, read correctly, remains the best available prediction of what the pump will actually do once installed.

FAQ

What is shutoff head on a pump curve?

Shutoff head is the head a pump develops when it delivers zero flow, such as against a closed discharge valve. It is the highest point of the head-flow curve and is useful for checking whether a system's static head can be overcome. It is not a normal operating point: prolonged operation at shutoff churns the trapped liquid, raises its temperature quickly, and can damage seals.

What does Best Efficiency Point (BEP) mean?

BEP is the flow rate at which the pump's efficiency curve peaks, meaning the pump converts the largest share of shaft power into useful liquid movement. Manufacturer guidance treats BEP as the ideal duty point because operation near it minimizes energy use, vibration, shaft deflection, and wear on bearings and seals.

Is it safe to run a pump at runout?

Runout is the far right end of the head-flow curve, the maximum flow the pump can deliver. It is a limit rather than a duty point: near runout the NPSH required climbs steeply, raising cavitation risk, and for most radial-flow pumps power draw rises toward motor overload. Manufacturers intend operation at runout only for limited, short-duty situations, so check the stated allowable operating region.

Why do pump curves use head instead of pressure?

Head is a measure of energy per unit weight, expressed as feet or meters of the pumped liquid. The pressure produced by a given head depends on the liquid's density, so stating performance in head lets a single curve remain meaningful for different fluids, and head values add up directly with static lift and friction losses when analyzing a system.

Why does my pump not deliver the flow shown on its curve?

The curve shows capability, not a guaranteed flow. An installed pump operates at the duty point, where its curve intersects the system curve of static head plus friction losses. If the actual flow differs from expectation, the pump is interacting with a system whose resistance differs from what was assumed, so read the intersection rather than the curve alone.

References

  1. U.S. Department of Energy, Industrial Technologies Program. Select an Energy-Efficient Centrifugal Pump, Energy Tips - Pumping Systems Tip Sheet #3 (October 2005). OSTI: https://osti.gov/biblio/1216271
  2. Wilo USA. Getting the Most Out of Your Pumps: Reading and Understanding the Centrifugal Pump Performance Curves. https://wilo.com/us/en_us/Training/On-Demand-Resources/Pump-Basics/Getting-the-Most-Out-of-Your-Pumps/
  3. Swetye, J. How to Read a Pump Curve (webinar), Pumps & Systems, January 28, 2016. https://www.pumpsandsystems.com/wp-content/uploads/sites/default/files/webinars/2016/01-28/How-to-Read-a-Pump-Curve20160128.pdf
  4. Bankston, D. Pump Curves, LSU AgCenter Publication 3241-H. https://www.lsuagcenter.com/~/media/system/9/2/3/5/923525275a3ff99d781ff0eec797e7a8/pub3241hpumpcurves.pdf

Related Terms

Leave a Reply

Your email address will not be published. Required fields are marked *