What are you working on?

Find a calculator, explore a formula, or learn the method.

THE ENGINEERING REFERENCE / GUIDE

Agitator Power Number: Estimating Power from Speed, Diameter, and Density

Short Answer

The agitator power number (Np) is a dimensionless coefficient that links shaft power to liquid density, the cube of rotational speed, and the fifth power of impeller diameter through P = Np·ρ·N³·D⁵. In fully turbulent baffled tanks Np is roughly constant for a given impeller, so a single value—about 5 for a Rushton-type disc turbine—turns speed, diameter, and density into an immediate power estimate.

Estimating how much power an agitator needs starts from one compact, dimensionless quantity: the power number. Once the power number of a given impeller is known, the shaft power required to turn it follows directly from three measurable quantities — liquid density, rotational speed, and impeller diameter — through the relation P = Np·ρ·N³·D⁵. This article explains what the power number represents, why speed and diameter enter the formula with the cube and the fifth power, how the impeller Reynolds number changes the value you should use, and how to carry out a practical estimate with a worked example.

What the Power Number Is

The power number, usually written Np, is a dimensionless characteristic of an impeller. In SI units it is defined as Np = P / (ρ·N³·D⁵), where P is the shaft power required to rotate the impeller in watts, ρ is the liquid density in kg/m³, N is the agitator speed in revolutions per second, and D is the impeller diameter in meters. Rearranged, it becomes the working estimation equation: P = Np·ρ·N³·D⁵ (My Engineering Tools).

Conceptually, the power number plays a role similar to a pipe friction factor: it condenses complicated three-dimensional flow and impeller geometry into a single coefficient. Values come from published correlations and charts, manufacturer data, or pilot trials. Industry guidance is candid about accuracy limits: the best way to pin down a power number is to run pilot-plant trials or ask the impeller manufacturer, but reference tables are widely used for rough calculations in pre-project work and troubleshooting (My Engineering Tools).

One distinction matters throughout: the power given by this equation is shaft power — the mechanical power actually delivered to the impeller — not the electrical rating of the motor, which must additionally cover drive losses.

Why Speed, Diameter, and Density Enter the Formula

Experimental data on mixing have long shown that the power consumed by an impeller is proportional to the density of the fluid, the cube of the rotational speed, and the fifth power of the impeller diameter (University of Michigan, ChE 344). Those exponents have immediate practical consequences: doubling the agitator speed raises power roughly eightfold, and doubling the impeller diameter raises power roughly 32-fold, while density enters only linearly.

A common physical rationalization helps the exponents feel less arbitrary. The tip speed of an impeller scales with N·D, so the inertial (dynamic) pressure the blades generate scales with ρ·(N·D)². The volumetric flow the impeller sweeps scales with N·D times D² (a cross-sectional area). Multiplying pressure by flow gives power proportional to ρ·N³·D⁵. This is a rationale rather than a proof — the relationship is ultimately established from experiment — but it explains why large, fast impellers are so costly to drive.

A unit caution belongs here because it is the most frequent arithmetic error: N must be in revolutions per second, not revolutions per minute. A speed entered in rpm overstates power by a factor of 60³ = 216,000.

The Impeller Reynolds Number and Flow Regime

The appropriate power number depends on how the liquid flows in the tank, which is characterized by the impeller Reynolds number NRe. It is obtained by substituting the impeller diameter D for the pipe diameter and the impeller tip speed N·D for the fluid velocity in the familiar pipe Reynolds number, giving NRe = ρ·N·D²/μ, where μ is the dynamic viscosity (University of Michigan, ChE 344).

The Reynolds number classifies tank flow as laminar, transitional, or turbulent. Across these regimes the power number is not constant: it decreases as the Reynolds number increases (CerCell). For standard impellers, commonly used classifications place fully turbulent behavior above roughly NRe ≈ 10,000. In that fully turbulent region — the usual situation for low-viscosity liquids in adequately sized vessels — the power number becomes approximately constant for a given impeller geometry, so density, speed, and diameter alone determine the power.

In the laminar regime (low NRe, typical of very viscous liquids), the power number is approximately inversely proportional to the Reynolds number. Substituting that relationship into the power equation shows that power then scales approximately as μ·N²·D³: viscosity dominates, density drops out, and the fifth-power diameter dependence softens to a cube. The transitional regime in between is the least predictable; designers normally read a power curve (a plot of Np versus NRe for the specific impeller) rather than using a single constant.

Published turbulent values also assume baffled tanks — vertical strips on the vessel wall that interrupt rotational swirl. In an unbaffled tank the liquid tends to rotate with the impeller, the flow pattern changes, and the power draw falls below the tabulated value.

Typical Power Numbers for Common Impellers

For a fully turbulent liquid in a standard baffled tank, common literature values for the power number are approximately as follows. They are approximations, and the exact geometry of each impeller shifts them somewhat.

Impeller typeTypical Np (fully turbulent, baffled)Primary flow pattern
Six-blade disc turbine (Rushton-type)≈ 5Radial
Pitched-blade turbine (45°, four to six blades)≈ 1.3–1.7Mixed axial–radial
Marine-type propeller≈ 0.3–0.4Axial
Hydrofoil impeller≈ 0.3–1Axial

The spread between these values reflects a real trade-off: radial-flow disc turbines impose high power per unit of pumping, while hydrofoils and propellers move liquid efficiently at low power draw. Actual values change with the ratio of impeller to tank diameter, blade width and count, off-bottom clearance, and degree of baffling, so treat the table as a screening reference. Reference tables compiled for common agitators, vendor datasheets, and an online power number calculator are useful when a quick check is needed, while design-critical work should rely on manufacturer data or pilot trials (My Engineering Tools).

Estimating Power Step by Step

  1. Gather the inputs. Liquid density ρ, liquid viscosity μ (needed for the regime check), impeller diameter D, and agitator speed N. Note the vessel geometry and whether standard baffles are installed.
  2. Convert to consistent SI units. Divide rpm by 60 to obtain revolutions per second, use kg/m³ for density (note that 1 g/dm³ equals 1 kg/m³, the density unit used by the CerCell calculator), and meters for diameter.
  3. Check the flow regime. Compute NRe = ρ·N·D²/μ and judge whether the duty is laminar, transitional, or turbulent.
  4. Select the power number. For turbulent operation in a baffled tank, take the approximate constant for the impeller type from a table or vendor. For laminar flow, use Np ≈ K/NRe with a geometry factor K. For transitional flow, read a power curve for the specific impeller.
  5. Compute the shaft power. Multiply out P = Np·ρ·N³·D⁵, which yields watts when SI units are used.
  6. Size the drive. Remember that friction in bearings, couplings, and gearboxes and the motor’s electrical losses must be accounted for on top of the shaft power when selecting a motor (CerCell). Choose the next standard motor size above the total.
  7. Validate where it matters. For anything beyond screening, compare against vendor power curves or pilot data, since geometry details can move the true value noticeably.

A Worked Example

The following example is a hypothetical screening calculation, not a specific installation. Consider a baffled pilot vessel holding a water-like product with ρ = 1000 kg/m³ and μ ≈ 0.001 Pa·s, agitated by a six-blade disc turbine with D = 0.5 m turning at N = 120 rpm.

Convert the speed: 120 rpm ÷ 60 = 2 revolutions per second. Check the regime: NRe = 1000 × 2 × 0.5² / 0.001 = 500,000, comfortably in the fully turbulent range, so a power number of about 5 is reasonable for this classic baffled geometry. Then:

P = 5 × 1000 kg/m³ × 2³ × 0.5⁵ = 5 × 1000 × 8 × 0.03125 = 1250 W ≈ 1.25 kW of shaft power.

The cube-law sensitivity is worth seeing immediately: if the same impeller ran at 180 rpm (3 rev/s), power would rise by a factor of (3/2)³ = 3.375 to roughly 4.2 kW. After adding drive losses, a motor comfortably larger than 1.25 kW would be selected for the base case — standard practice keeps a margin rather than sizing a motor at exactly the calculated shaft load.

Limitations and Common Mistakes

  • rpm entered instead of rev/s. The single most common error; it overstates power by a factor of 216,000.
  • Using tank diameter instead of impeller diameter. D in the correlation is the impeller diameter, which is typically a fraction of the vessel diameter.
  • Applying the turbulent constant to viscous duties. With the same impeller as the worked example but a liquid of μ = 1 Pa·s, NRe would fall to about 500 — transitional territory where Np = 5 no longer applies and a power curve is needed.
  • Unbaffled or partially baffled tanks. Swirling flow lowers the power draw below tabulated values and changes the flow pattern, so baffled-tank values should not be assumed.
  • Non-Newtonian liquids. Viscosity varies with shear rate, so a single NRe based on a constant μ is unreliable; apparent-viscosity methods and vendor guidance are preferred.
  • Gas-sparged operation. Dispersing gas changes the power draw, typically lowering it relative to the ungassed value, so gassed systems need specific data.
  • Multiple impellers on one shaft. Power does not always scale as a simple sum because the impellers interact; vendor correlations handle this case.
  • Confusing shaft power with motor rating. The calculation gives shaft power; gearbox, bearing, coupling, and electrical losses must be added for motor selection (CerCell).

Why the estimate matters beyond motor sizing: drive energy is a significant contributor to the operating costs of agitated reactors. An analysis of glass-lined chemical reactors by THALETEC identifies the energy supplied to the agitator drive, together with circulation and temperature control of service media, as a meaningful share of operating costs — so even a screening-grade power estimate feeds directly into operating-expense and efficiency decisions (THALETEC).

Practical Takeaways

The power number turns a messy fluid-dynamics problem into a one-line calculation: P = Np·ρ·N³·D⁵, with N in revolutions per second and D the impeller diameter. For low-viscosity liquids in baffled tanks, geometry-specific constants (about 5 for a Rushton-type disc turbine, roughly 0.3–1.7 for axial and mixed-flow impellers) give serviceable screening estimates. Always check the impeller Reynolds number before choosing a value, convert speeds and units carefully, add drive losses when sizing the motor, and verify against vendor or pilot data whenever the estimate will drive an equipment purchase or a scale-up decision.

FAQ

Why is power proportional to the cube of speed and the fifth power of diameter?

The proportionality is established experimentally: measured impeller power scales with fluid density, speed cubed, and diameter to the fifth power. A common rationalization is that blade tip speed scales with N·D (making dynamic pressure scale with ρ·(N·D)²) while the swept flow scales with N·D·D², so their product scales as ρ·N³·D⁵.

Should agitator speed be entered as rpm or revolutions per second?

In the SI power equation P = Np·ρ·N³·D⁵, speed N must be in revolutions per second. Divide a speed in rpm by 60 before using it; entering rpm directly overstates the power by a factor of 216,000.

Does the power number change with viscosity?

Yes. The power number decreases as the impeller Reynolds number increases, and it is only approximately constant for a given impeller in the fully turbulent regime typical of low-viscosity liquids in baffled tanks. For viscous, laminar duties the power number rises sharply, and in the transitional regime a power curve for the specific impeller should be used.

Is the calculated shaft power the same as the motor size I need?

No. The equation gives shaft power at the impeller. Motor selection must also cover mechanical losses in bearings, couplings, and gearboxes as well as electrical losses, and practice is to choose the next standard motor size above the total rather than sizing exactly at the calculated load.

References

  1. Mastering Agitator Power Numbers: Essential Reference Guide — My Engineering Tools. https://myengineeringtools.com/Piping/Power_Number_Agitator.html
  2. Power Number Calculator — CerCell A/S. https://cercell.com/bioreactor-support/power-numbers-details/power-number-calculator/
  3. ChE 344 — Mixing in Chemical Reactors: Dimensionless Numbers — University of Michigan. https://public.websites.umich.edu/~elements/01chap/html/reactors/mixing/dn.htm
  4. Performance Requirements of a Chemical Agitated Reactor — THALETEC (Thale-mail 161). https://thaletec.com/en/news/uebersicht-newsletter/161/performance-requirements-of-an-chemical-agitated-reactor

Related Terms

Leave a Reply

Your email address will not be published. Required fields are marked *